product detail
CAD Digital Load Cell
10-20-30 t
Overview;
Model CAD has double · sockets, cable connection is done by jumping from one load cell to another one. It does not require junction box so it is very easy to change in case of fault.
Model CAD load cell, is based on the shear force principle to measure forces in the compression direction. It has been developed for use in high capacity, electronic weight and force measurement applications in industrial environments. Thanks to its’ perfect and rugged body, it offers high resistance to side forces and overload conditions.
Stainless steel body is resistant to corrosion. CAD load cell is suitable for heavy industrial conditions and chemical environments. It finds application in high capacity vehicle scales, platform scales, tank weighing systems and process weighing applications.
When compared to other brand digital load cells, the most important advantage of CAD load cell is that it bears an electronic anglemeter inside. With this feature, the technician is alerted by colored LEDs for proper assembly during installation.
Main problem in truck scales is side forces. Platform elongation due to thermal expansion of temperature differences between summer and winter change and platform deformation due to load distribution causes errors in measurement. In both cases, the load cells which are placed perpendicular to the ground becomes athwart and may cause measurement error. With thanks to the patented angle compensation Technology of Esit, vertical deflection angle of the load cell is detected via sensors to ensure an accurate weight measurement.
CAD load cell is 80% more resistant to side forces than other load cells working with column type principle. Particularly, the major
Features;
- Certified to OIML R60 standards
- Welded hermetic sealed body
- %100 resistant to side forces
- %300 resistant to over load
- IP68 industrial protection
- Lightning Protection
- Installation angle compensation
- RS485 communication
- Automatic corner calibration from indicator
- Measurement error detection
- 24 bit A/D converter
Specifications
Maximum capacities (Emax) | t | 10, 20, 30 | ||||
Accuracy class (OIML R 60) |
|
|||||
Maximum number of verification intervals() |
|
|||||
Minimum verification interval () |
|
|||||
Combined error | % | ≤ ±0.02 ≤ ±0.012 ≤ ±0.012 ≤ ±0.01 | ||||
Creep error over 30 min.(DR) | %Emax |
|
||||
Maximum safe overload | %Emax | 150 | ||||
Maximum safe sideload | %Emax | 100 | ||||
Ultimate load | %Emax | 300 | ||||
Stretching(Emaxyükte) | mm | ≤ 0.3 | ||||
Excitation voltage(Umax) | V | 12-24 | ||||
Excitation Current | mA | 100 | ||||
Output signal (at nominal load) | Sayım | 200 000 | ||||
Analog/Digital converter (sigma delta) | bit | 24 | ||||
Analog/Dijital converter speed | Hz | 1 or 200 | ||||
Asynchronous communication speed | Baud | 115.200 | ||||
Data interface | Semi Doublex | RS 485 | ||||
Angle measurement error | Degree | 0.1 | ||||
Inclination angle error display | 2 pieces 3 colored Led | |||||
Insulation voltage | V | 2500 | ||||
Compensated temperature range | °C | -10…+40 | ||||
Operating temperature range | °C | -40…+70 | ||||
Load cell material | Stainless Steel | |||||
Sealing (EN60529) | IP68 | |||||
Weight | kg | 8 |