LCA-D Transmitter for strain gauges

Explanation
LCA-D strain gauge amplifiers measure the weight of various tanks and similar devices, allowing remote monitoring of all measurements in the most cost-effective way.
The weights of one or more units weighed by strain gauges can be monitored both on the LCA-D devices mounted next to the weighing system, and remotely via a computer.
LCA-D features the possibility of computer setting of all parameters via the Modbus communication protocol. Built-in Modbus communication provides remote access and parameter setting. This allows monitoring and programming of several LCA devices connected to the same communication bus from a single control point, such as a PC or PLC.
Two software have been developed to communicate with the LCA devices. The first one, Dlms_VP (Digital Load Cell Measurement System Virtual Panel), can communicate with only one LCA device and set all parameters remotely. The second, Dlms_NW (Digital Load Cell Measurement System Network), allows monitoring of several LCA amplifiers simultaneously. Through Dlms_NW, several networked computers can display the same data.
The device’s aluminum housing allows it to be used even in dusty, humid and corrosive environments.

Features
• Dust- and moisture-proof aluminum housing
• Illuminated LCD display
• Membrane keyboard, dust and moisture resistant
• Tare, reset, function and setting buttons
• Reset over the entire measuring range
• Setup of the gain for the strain gauge output
• Digital linearization
• Digital temperature compensation
• Remote access to all internal parameters (Modbus)
• RS232 / RS485 serial output

Options
• 2 internal relays
• Analog output
• Single LCA Device Communication Software
• Multiple LCA Device Communication Software
• Digital Temperature Compensation

Category Specification
Accuracy
Class of accuracy (OIML) 7000d (III)
Input sensitivity 0.5µV/digit
Sensitivity %0.003
Null and gain stability 3.6ppm/°C
A/D converter 24-bit Sigma-Delta
Digital filter Adjustable digital filtering
Reporting frequency 50Hz
Strain gauge
Number of strain gauges supported 8 pieces (350Ω)
Analog Input Range ± 160mV/V
Power supply voltage for strain gauges 10V DC
Work Environment
Operating Temperature (OIML) -10°C to +40°C
Storage temperature -20°C to +70°C
Supply voltage and power 10-35V DC, 5W
Operator Interface and Display
Keyboard Dust and moisture resistant membrane keyboard with 3 time keys
Weight Display 4.5mm, 40-pixel, green LCD, 2×16 characters
Feature indicator
Program indicator
Body
Material and Security Class Aluminium, IP66
Weight 1 kg
Packaging Weight and Dimensions 1.1 kg, 15x24x6 cm
Communication Default                                                    Optional
Serial communication port RS232 / RS485 –
Parallel printer output
Binary (BCD) output
Output for external display
Digital Input/Output – 2 outputs (250V/2A relay)
Analog output – 4-20mA
BCD and digital I/O options cannot be used simultaneously. Areas of application Tank weighing systems Overload control systems Chemical and petrochemical industry