Dynamic railway wagon scale – DR-B
Overview
DR-B is an automatic measuring system designed for dynamic towing of freight wagons, without the need to disconnect from the train composition.
• Measures the weight of each axle in motion
• Calculates the total weight of the wagon and whole composition
• Allows determination of net weight by reweighing or entered tare
• Installed on railway in loading and unloading areas
• Data is transmitted in real time to a computer system
• Software processes and prints the results
Features
• Rubber supports
• Lightning protection
• Steel cable sheaths
• Dust, water and weather resistance
• High resistance to overloads and dynamic loads
• Quick and easy installation
• Classification of the wagons
• Enter composition data
• Record permanent tare
• Add up to 3 additional columns
• Visualize weight and average speed
• Place a company logo on the printouts
• Manage users
• View and print records for a selected period
• References by company, date, number wagon, direction, material
• Tabular data entry
• Option: Entry of wagon number by image
Measurement accuracy
• ±0.5% for total train weight
• ±1% for the weight of an individual wagon
Speed ​​range
• Minimum: 2 km/h
• Maximum: 20 km/h
Accessories
• PWI-X Indicator
Options
• Automatic vehicle recognition
• Printer
• Explosion proof scale (Ex Proof)
• Camera system
Model | Rated capacity (tons) | Minimum capacity (kg) | Step e=d* (kg) | Platform size (m) | Platform | Number of strain gauges | Model strain gauges | Junction Box (J-Box) | Indicator |
O30T DR/B 1812 | 60 | 1000 | 50 | 1.8 x 3.50 | Steel | 4 | HSC | J-4 | LCA |
Feature | Value |
Model | HSC |
Protection Class | IP68 |
Installation Kits | HSC-EL |
Fixed operating temperature range | -10°C … +40°C |
Operating Temperature Range | -40°C … +80°C |
Feature | Value |
Model | LCA |
Protection Class | IP54 |
Supply voltage and power | 90–265VAC, 60W |
Operating temperature range | -10°C … +40°C |
Parameter | Value |
Protection Class | IP66 |
Material | Aluminum |
Fixed temperature range | -10°C to +40°C |
Operating temperature range | -40°C to +80°C |
Power supply voltage and endurance | 220VAC |
* Multi-range measurement option available. ** Detailed information on strain gauges and mounting kits can be found in the strain gauges and mounting kits catalog. *** Detailed information on indicators used with truck scales can be found in the Indicators and Controls Catalog |