Overview
With its updated hardware, bright display and specialized hopper scale software, the new ECI indicator offers functionality, performance and convenience at a level that far exceeds industry standards. Along with the standard features of the ECI indicator, the ECI-HS model provides adjustable coarse-to-fine dosing, quantity dosing, flow measurement and automatic shot calculation for easy automation.
Explanation
Calibration:
With the standard “Calibration Doctor” function, the ECI indicator allows easy calibration while checking its quality. This prevents errors or incomplete calibration. Additionally, calibration can be performed with reference weights, digitally by inputting values, or via the mV input of a strain gauge. Since the indicator allows a backup copy of the calibration values ​​to be stored on the main board, these values ​​can be restored in case of failure.
Special Filtering (gResolver Filtering):
The ECI indicator includes special interference filtering software (gResolver Special Filtering). This technology eliminates harmful vibrations that can affect the towing process, ensuring both precision and speed in measurements.
Features
• Hopper scale program
• Quantity dosing or flow measurement
• Coarse-fine dosing
• Built-in card with four relays
• New bright graphic display showing the filling process
• Automatic calculation of launches
• Alarm when deviation from permissible limits
• Adaptive, indexed menu
• Easy connection via connectors (without soldering)
• 1600 Hz measurement frequency / 800 Hz data output frequency
• USB reporting, updating, backup and archiving of calibration
• Ability to transfer calibration data to other devices
• Multilingual interface
• gResolver – multi-frequency vibration filtering technology
• Easy calibration (mV, factory, factor, digital)
• Smart plug-and-play option cards and module expansions
• Galvanically isolated communication ports
• Built-in thermometer
• Service menu (diagnostics only)
• Printer support
• USB, RS232 serial interface and external display output
Options
• Ethernet/IP communication card
• Modbus TCP communication card
• Profibus communication card (DP slave)
• Profinet IO communication card
• RS232 & RS485/RS422 serial interface (Modbus)
Sensitivity | |
Accuracy class (OIML approved) | 10000d (III) |
Input sensitivity | 0.5uV/d |
Sensitivity | 0.0015 % FS |
Null and gain stability | 2 ppm/°C |
A/D converter | 24-bit Sigma-Delta |
Digital Filter | gResolver (Smart Adaptive FIR Filter) |
Read Frequency | 6.25-800 Hz |
Strain Gauges | |
Number of allowed strain gauges | 10 pieces 350 Ω or 32 pieces 1100 Ω |
Analog input range | (-25mV to +25mV) or (-1.6V to +1.6V) |
Supply voltage | 10V DC |
Environment | |
Operating temperature range | -10°C to +40°C |
Temperature storage range | -20°C to +70°C |
Operating voltage and power | 12-24 VDC, 5W |
Operating functions and display | |
Keyboard | 5 touch buttons, special function according to the situation |
Weight Display | 4.5″ Vivid graphic display |
Function display | Gross, Net, Steady, Zero, Unit (g, kg, t, lb, lt, mV/V, m3) |
Program display | Download Program |
Body | |
Material and Protection Class | Impact-resistant plastic (PC), IP54 (Front panel IP65) |
Weight | 0.36 kg (Standard) |
Package weight and dimensions | 0.55 kg (Standard) – 18×12.5×11 cm |
Communication Standard Optional | |
Serial communication output | RS232 RS422 / RS485 |
Printer output | Serial connected printer          – |
Output for remote display | √                                                                  – |
Digital Inputs / Outputs | – 4-20mA / 0-10V (16bit) |
Internal relay | 4 relay card                               – |