600 kg
Explanation:
SPA is a platform-type strain gauge designed for precise single-point weight measurement. It has internal thermal compensation that corrects deviations caused by temperature changes and is resistant to inertial forces.
Made of aluminum alloy with an anti-corrosion coating and with a sensing area insulated with a special chemical material, the sensor meets the IP55 protection standard. Suitable for platforms up to 80 × 80 cm, SPA is used in conveyor scales, roller scales and process scales.
Features:
Easy to install
Industrial protection IP55
Accessories:
J Box Connection
| Model | Capacity | Minimum division | Maximum overload capacity | 
| SPA 600 | 600 kg | 120 g | 600 kg | 
| Parameter | Unit | Value | 
| Maximum capacity (Emax) | kg | 600 | 
| Accuracy (OIML R60) | C3 | |
| Maximum number of verification intervals | 3000 | |
| Minimum verification interval | Emax/5000 | |
| Combined error | % | ≤ ±0.02 | 
| 30 min crawl error (DR) | % Emax | 0.0012 | 
| Minimum load | % Emax | 0 | 
| Maximum allowable overload | % Emax | 100 | 
| Maximum allowable lateral load | % Emax | 100 | 
| Limited load | % Emax | 150 | 
| Stretch (Emax) | mm | ≤0.7 | 
| Maximum supply voltage (Umax) | V | 10 | 
| Nominal output signal (Cn) | mV/V | 2 ±0.1% | 
| Balance at zero load | %Cn | ≤ ±1.0 | 
| Input resistance | Ω | 409±6 | 
| Output Resistance | Ω | 350 ±3.5 | 
| Insulation resistance | MΩ | ≥500 | 
| Compensated temperature range | °C | -10…+40 | 
| Operating temperature range | °C | -40…+80 | 
| Strain gauge material | Aluminum | |
| Sealing (EN60529) | IP55 | |
| Cable length | m | 3±%3 | 
| Cable diameter | mm | 6 | 
| Weight | kg | 0.72 | 
| Package dimensions / weight | cm/kg | 7x18x12 / 1.8 |