20–40–80–120 kg
Description:
SSP is a platform-type strain gauge designed for single-point measurement, with high accuracy and built-in thermal compensation that minimizes errors caused by temperature changes.
Made of stainless steel, the SSP is suitable for low capacity platform scales in food, chemical and petrochemical industry. Supports center or under platform mounting up to 50 × 50 cm.
Features:
• Easy installation
• Stainless steel
• Industrial protection IP67
Accessories:
• J Box
Model | Capacities | Minimum division | Maximum overload capacity |
SSP 20 | 20 kg | 2 years | 20 kg |
SSP 40 | 40 kg | 4 years | 40 kg |
SSP 80 | 80 kg | 8 years | 80 kg |
SSP 120 | 120 kg | 12 yrs | 120 kg |
* This is outside the scope of the SSP 10 OIML R60 certification. |
Specification | Unit | Value |
Maximum capacities (Emax) | kg | 20, 40, 80, 120 kg |
Accuracy (OIML R60) | C1, C3 | |
Maximum number of verification intervals | 1000, 3000 | |
Minimum verification interval | Emax/5000, Emax/10000 | |
Combined error | % | ≤ ±0.05, ≤ ±0.02 |
Saturation error for 30 min (DR) | %Emax | 0.008 %Emax |
Minimum load | %Emax | 0 %Emax |
Maximum safe overload | %Emax | 100 %Emax |
Maximum Safe Side Load | %Emax | 100 %Emax |
Final Load | %Emax | 200 %Emax |
Extension (Emax) | mm | ≤ 0.6 mm |
Maximum excitation voltage (Umax) | Â V | 15 V |
Nominal Output (Cn) | mV/V | 2 ± 5% mV/V |
Balance to zero | %Cn | ≤ ±1.0 % Cn |
Input resistance | Ω | 385 ±20 Ω |
Output resistance | Ω | 351 ±3 Ω |
Insulation resistance |  MΩ | ≥ 500 MΩ |
Temperature compensation range | °C | -10…+40 °C |
Operating temperature range | °C | -40…+80 °C |
Sensor Material | Stainless steel | |
Sealing (EN60529) | IP67 | |
Cable length | m | 3 ±3% m |
Cable diameter | mm | 5mm |
Weight | kg | 0.8 kg |
Package Dimensions / Weight | Â cm/kg | 21.5×12.5×7.5 cm / 1 kg |