{"id":2907,"date":"2025-06-29T22:50:29","date_gmt":"2025-06-29T19:50:29","guid":{"rendered":"https:\/\/espa-systems.com\/shop\/uncategorized\/lca-d-predavatel-za-tenzometrichni-datchiczi-2\/"},"modified":"2025-09-10T04:59:38","modified_gmt":"2025-09-10T01:59:38","slug":"lca-d-predavatel-za-tenzometrichni-datchiczi-2","status":"publish","type":"product","link":"https:\/\/espa-systems.com\/en\/shop\/indicators-and-control-devices\/weight-indicators\/lca-d-predavatel-za-tenzometrichni-datchiczi-2\/","title":{"rendered":"LCA-D Transmitter for strain gauges"},"content":{"rendered":"<p data-start=\"128\" data-end=\"1459\"><strong data-start=\"128\" data-end=\"141\">Explanation<\/strong><br data-start=\"141\" data-end=\"144\" \/>LCA-D strain gauge amplifiers measure the weight of various tanks and similar devices, allowing remote monitoring of all measurements in the most cost-effective way.<br data-start=\"335\" data-end=\"338\" \/>The weights of one or more units weighed by strain gauges can be monitored both on the LCA-D devices mounted next to the weighing system, and remotely via a computer.<br data-start=\"539\" data-end=\"542\" \/>LCA-D features the possibility of computer setting of all parameters via the Modbus communication protocol. Built-in Modbus communication provides remote access and parameter setting. This allows monitoring and programming of several LCA devices connected to the same communication bus from a single control point, such as a PC or PLC.<br data-start=\"916\" data-end=\"919\" \/>Two software have been developed to communicate with the LCA devices. The first one, Dlms_VP (Digital Load Cell Measurement System Virtual Panel), can communicate with only one LCA device and set all parameters remotely. The second, Dlms_NW (Digital Load Cell Measurement System Network), allows monitoring of several LCA amplifiers simultaneously. Through Dlms_NW, several networked computers can display the same data.<br data-start=\"1354\" data-end=\"1357\" \/>The device&#8217;s aluminum housing allows it to be used even in dusty, humid and corrosive environments.<\/p>\n<p data-start=\"1461\" data-end=\"1913\"><strong data-start=\"1461\" data-end=\"1479\">Features<\/strong><br data-start=\"1479\" data-end=\"1482\" \/>\u2022 Dust- and moisture-proof aluminum housing<br data-start=\"1522\" data-end=\"1525\" \/>\u2022 Illuminated LCD display<br data-start=\"1546\" data-end=\"1549\" \/>\u2022 Membrane keyboard, dust and moisture resistant<br data-start=\"1598\" data-end=\"1601\" \/>\u2022 Tare, reset, function and setting buttons<br data-start=\"1648\" data-end=\"1651\" \/>\u2022 Reset over the entire measuring range<br data-start=\"1691\" data-end=\"1694\" \/>\u2022 Setup of the gain for the strain gauge output<br data-start=\"1754\" data-end=\"1757\" \/>\u2022 Digital linearization<br data-start=\"1781\" data-end=\"1784\" \/>\u2022 Digital temperature compensation<br data-start=\"1820\" data-end=\"1823\" \/>\u2022 Remote access to all internal parameters (Modbus)<br data-start=\"1882\" data-end=\"1885\" \/>\u2022 RS232 \/ RS485 serial output<\/p>\n<p data-start=\"1915\" data-end=\"2111\"><strong data-start=\"1915\" data-end=\"1924\">Options<\/strong><br data-start=\"1924\" data-end=\"1927\" \/>\u2022 2 internal relays<br data-start=\"1946\" data-end=\"1949\" \/>\u2022 Analog output<br data-start=\"1965\" data-end=\"1968\" \/>\u2022 Single LCA Device Communication Software<br data-start=\"2018\" data-end=\"2021\" \/>\u2022 Multiple LCA Device Communication Software<br data-start=\"2072\" data-end=\"2075\" \/>\u2022 Digital Temperature Compensation<\/p>\n","protected":false},"excerpt":{"rendered":"<table>\n<thead>\n<tr>\n<td><strong>Category<\/strong><\/td>\n<td><strong>Specification<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Class of accuracy (OIML)<\/td>\n<td>7000d (III)<\/td>\n<\/tr>\n<tr>\n<td>Input sensitivity<\/td>\n<td>0.5\u00c2\u00b5V\/digit<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity<\/td>\n<td>%0.003<\/td>\n<\/tr>\n<tr>\n<td>Null and gain stability<\/td>\n<td>3.6ppm\/\u00c2\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>A\/D converter<\/td>\n<td>24-bit Sigma-Delta<\/td>\n<\/tr>\n<tr>\n<td>Digital filter<\/td>\n<td>Adjustable digital filtering<\/td>\n<\/tr>\n<tr>\n<td>Reporting frequency<\/td>\n<td>50Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Strain gauge<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Number of strain gauges supported<\/td>\n<td>8 pieces (350\u00ce\u00a9)<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Range<\/td>\n<td>\u00c2\u00b1 160mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Power supply voltage for strain gauges<\/td>\n<td>10V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Work Environment<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature (OIML)<\/td>\n<td>-10\u00c2\u00b0C to +40\u00c2\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>-20\u00c2\u00b0C to +70\u00c2\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Supply voltage and power<\/td>\n<td>10-35V DC, 5W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Operator Interface and Display<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Keyboard<\/td>\n<td>Dust and moisture resistant membrane keyboard with 3 time keys<\/td>\n<\/tr>\n<tr>\n<td>Weight Display<\/td>\n<td>4.5mm, 40-pixel, green LCD, 2&#215;16 characters<\/td>\n<\/tr>\n<tr>\n<td>Feature indicator<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Program indicator<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td><strong>Body<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Material and Security Class<\/td>\n<td>Aluminium, IP66<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1 kg<\/td>\n<\/tr>\n<tr>\n<td>Packaging Weight and Dimensions<\/td>\n<td>1.1 kg, 15x24x6 cm<\/td>\n<\/tr>\n<tr>\n<td><strong>Communication<\/strong><\/td>\n<td><strong>Default\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0\u00c2\u00a0 Optional<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Serial communication port<\/td>\n<td>RS232 \/ RS485 &#8211;<\/td>\n<\/tr>\n<tr>\n<td>Parallel printer output<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Binary (BCD) output<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Output for external display<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Digital Input\/Output<\/td>\n<td>&#8211; 2 outputs (250V\/2A relay)<br \/>\n<\/tr>\n<tr>\n<td>Analog output<\/td>\n<td>&#8211; 4-20mA<br \/>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>BCD and digital I\/O options cannot be used simultaneously.<\/em><\/p>\n<p>Areas of application<\/p>\n<p>Tank weighing systems<br \/>\nOverload control systems<br \/>\nChemical and petrochemical industry<\/p>\n","protected":false},"featured_media":2195,"template":"","meta":[],"product_brand":[],"product_cat":[238,241],"product_tag":[],"class_list":{"0":"post-2907","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-indicators-and-control-devices","7":"product_cat-weight-indicators","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/product\/2907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/media\/2195"}],"wp:attachment":[{"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/media?parent=2907"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/product_brand?post=2907"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/product_cat?post=2907"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/espa-systems.com\/en\/wp-json\/wp\/v2\/product_tag?post=2907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}