product detail
HSC-V 200t Load Cell
200 t
3D model
Explanation;
The HSCV shear beam load cell has been developed for use in high capacity, compression type electronic weight and force measurement applications in industrial environments. The precise and rugged HSCV load cell offers high resistance to side forces and overload conditions.
The HSCV load cells are suitable for severe industrial conditions and they find application in high capacity vehicle scales, railway scales, tank weighing systems and process weighing applications. With its steel alloy construction coated with corrosion-retardant paint as well as its strain gauge area welded with a stainless steel cover, HSCV is protected to IP68 standards meaning that they are fully immersible.
Features;
- Resistant to side forces
- Heavy duty
- Hermetic-sealed strain gauge area
- Thin profile body
- IP68 industrial protection
Accessories;
Models
Model | Capacities | Minumum Division | Maximum Overload Capacity |
HSCV 200 | 200000 kg | 40 kg | 300000 kg |
Specifications
Maximum capacities (Emax) | kg | 200000 |
Accuracy (OIML R60) | C1 | |
Maximum number of verification intervals () | 1000 | |
Minimum verification interval () | Emax/3500 | |
Combined error | % | ≤ ±0.05 |
Creep error over 30 min. (DR) | %Emax | 0.0039 |
Minimum load | %Emax | 0 |
Maximum safe overload | %Emax | 150 |
Maximum safe sideload | %Emax | 50 |
Ultimate load | %Emax | 250 |
Stretching (Emax) | mm | ≤ 0.3 |
Maximum excitation voltage (Umax) | V | 15 |
Rated output (Cn) | mV/V | 2 ±0.5% |
Zero balance | %Cn | ≤ ±1.0 |
Input Resistance | Ω | 760±20 |
Output Resistance | Ω | 700±3 |
Insulation resistance | MΩ | ≥500 |
Compensated temperature range | °C | -10…+40 |
Operating temperature range | °C | -40…+80 |
Load cell material | Steel | |
Sealing (EN60529) | IP68 | |
Cable length | m | 13±%3 |
Cable diameter | mm | 8 |
Weight | kg | 37 |
Package dimensions / weight | cm/kg | 45x45x20 / 40 |