product detail
MSP Load Cell
8-15-20-30-40-60-80-100 kg
3D model
Explanation;
MSP platform type load cell is capable of measuring weights from a single point. It offers a high level of accuracy and features an internal thermal compensation that corrects output drifts due to ambient temperature variations.
Stainless steel MSP load cell has been developed for use in platform scales, for low capacity weighing applications in food, chemical and pharmaceutical industries. Suitable for platform sizes of up to 40 x 40 cm, MSP may be mounted in the center of or under the platform.
Features;
- Easy-to-mount
- Stainless Steel
- IP67 industrial protection
- Certified to OIML R60 standards
Models
Type | Capacities | Minumum Division | Maximum Safe Overload |
MSP 8 | 8 kg | 0.4 g | 12 kg |
MSP 15 | 15 kg | 0.75 g | 22,5 kg |
MSP 20 | 20 kg | 1 g | 30 kg |
MSP 40 | 40 kg | 2 g | 60 kg |
MSP 60* | 60 kg | 3 g | 90 kg |
MSP 80* | 80 kg | 4 g | 120 kg |
MSP 100* | 100 kg | 5 g | 150 kg |
Specifications
Maximum capacities (Emax) | kg | 8, 15, 20, 30, 40, 60, 80, 100 |
Accuracy (OIML R60) | C3 | |
Maximum number of verification intervals () | 3000 | |
Minimum verification interval () | 0.005 %Emax | |
Combined error | % | ≤ ±0.033 |
Creep error over 30 min. (DR) | %Emax | 0.0061 |
Minimum load | %Emax | 0 |
Maximum safe overload | %Emax | 150 |
Maximum safe sideload | %Emax | 100 |
Ultimate load | %Emax | 200 |
Stretching (Emax) | mm | ≤0.3 |
Maximum excitation voltage (Umax) | V | 15 |
Rated output (Cn) | mV/V | 2 ±10% |
Zero balance | % Cn | ≤ ±1.0 |
Input Resistance | Ω | 380 ±20 |
Output Resistance | Ω | 351 ±3 |
Insulation resistance | MΩ | ≥500 |
Compensated temperature range | °C | -0…+40 |
Operating temperature range | °C | -40…+80 |
Load cell material | Stainless Steel | |
Sealing (EN60529) | IP67 | |
Cable length | m | 3 |
Cable diameter | mm | 5 |
Weight | kg | 0.26 |
Package dimensions / weight | cm/kg | 17.5x9x5 / 0.3 |