product detail
SPA 3-50 Load Cell
3-6-10-20-30-50 kg
3D model
Explanation;
SPA platform type load cell is capable of measuring weights from a single point. It offers a high level of accuracy and features an internal thermal compensation that corrects output drifts due to ambient temperature variations. It is resistant to momentum forces.
With its corrosion resistant, aluminum construction as well as its strain gauge area which is isolated with a special chemical material, SPA load cells are protected against water in accordance with IP55 standards. Suitable for platform sizes of up to 30 x 30 cm, SPA load cells are produced in various capacities (3, 6, 10, 20, 30 and 50 kg) and they may be mounted in the center of or under the platform. These platform type scales with one load cell find application in conveyor scales, roller scales and process weighing applications.
Features;
- Easy-to-mount
- IP55 industrial protection
Accessories;
Models
Model | Capacities | Minumum Division | Maximum Overload Capacity |
SPA 3 | 3 kg | 0.6 g | 3 kg |
SPA 6 | 6 kg | 1.2 g | 6 kg |
SPA 10 | 10 kg | 2.0 g | 10 kg |
SPA 20 | 20 kg | 4.0 g | 20 kg |
SPA 30 | 30 kg | 6.0 g | 30 kg |
SPA 50 | 50 kg | 10.0 g | 50 kg |
Specifications
Maximum capacities (Emax) | kg | 3, 6, 10, 20, 30, 50 | ||
Accuracy (OIML R60) |
|
|||
Maximum number of verification intervals () |
|
|||
Minimum verification interval () | % |
|
||
Combined error | %Emax | ≤ ±0.05 ≤ ±0.02 | ||
Creep error over 30 min. (DR) | %Emax | 0.012 | ||
Minimum load | %Emax | 0 | ||
Maximum safe overload | %Emax | 100 | ||
Maximum safe sideload | %Emax | 100 | ||
Ultimate load | %Emax | 150 | ||
Stretching (Emax) | mm | ≤0.8 | ||
Maximum excitation voltage (Umax) | V | 10 | ||
Rated output (Cn) | mV/V | 2 ±0.1% | ||
Zero balance | %Cn | ≤ ±1.0 | ||
Input Resistance | Ω | 409±6 | ||
Output Resistance | Ω | 350 ±3.5 | ||
Insulation resistance | MΩ | ≥500 | ||
Compensated temperature range | °C | -10…+40 | ||
Operating temperature range | °C | -40…+80 | ||
Load cell material | Aluminum | |||
Sealing (EN60529) | IP55 | |||
Cable length | m | 0.4±%3 | ||
Cable diameter | mm | 4 | ||
Weight | kg | 0.17 | ||
Package dimensions / weight | cm/kg | 4x15x5 / 0.2 |
Documents
SPA Load Cell Technical Drawing (.pdf)
SPA Application Graphic (.pdf)
You can use the VariCad program to open 2D & 3D technical drawings.
Download the program
Certificates
SSP-SP-SPA Gost (Russian) Type Approval
Industrial Scales :
PS 3-100 kg Desktop Scales With Single Load Cell Desktop Scales With Single Load Cell 6-15-30-60-100 kg
Industrial Scales :
PS 150-300 kg Scale With Single Load Cell Scale With Single Load Cell 150-300-600 kg